Übersichtsarbeiten - OUP 05/2013

Die Therapie distaler Radiusfrakturen beim älteren Menschen

28. Hutchinson DT, Strenz GO, Cautilli RA. Pins and plaster vs external fixation in the treatment of unstable distal radial fractures. A randomized prospective study. J Hand Surg Br 1995; 20: 365–372.

29. Roumen RM, Hesp WL, Bruggink ED. Unstable Colles’ fractures in elderly patients. A randomised trial of external fixation for redisplacement. J Bone Joint Surg Br 1991; 73: 307–11.

30. Keller M, Steiger R. [Open reduction and internal fixation of distal radius extension fractures in women over 60 years of age with the dorsal radius plate (pi-plate)]. Handchir Mikrochir Plast Chir 2006; 38: 82–89.

31. Yu YR, Makhni MC, Tabrizi S et al. Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study. J Hand Surg Am 2011; 36: 1135–1141.

32. Orbay JL and Fernandez DL. Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am 2004; 29: 96–102.

33. Voigt C, Lill H. [What advantages does volar plate fixation have over K-wire fixation for distal radius extension fractures in the elderly?]. Unfallchirurg 2006; 109: 845–6, 848–854.

34. Hakimi M, Jungbluth P, Windolf J et al. Functional results and complications following locking palmar plating on the distal radius: a retrospective study. J Hand Surg Eur Vol; 35: 283–288.

35. Chung KC, Squitieri L, Kim HM. Comparative outcomes study using the volar locking plating system for distal radius fractures in both young adults and adults older than 60 years. J Hand Surg Am 2008; 33: 809–819.

36. Windolf J, Hakimi M, Schädel-Höpfner M. Ergebnisse der palmaren winkelstabilen Plattenosteosynthese am distalen Radius. Trauma Berufskrankh 2008; 10: 236–240.

37. Walz M, Kolbow B, Auerbach F. Do fixed-angle T-plates offer advantages for distal radius fractures in elderly patients?. Unfallchirurg 2004; 107: 664–666, 668–670.

38. Hakimi M, Jungbluth P, Gehrmann S et al. [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock]. Unfallchirurg; 113: 210–216.

39. Kock H, Bandl WD, Chan T. [Experiences and results with the locked compression plate for 603 fractures of the distal radius]. Handchir Mikrochir Plast Chir 2005; 37: 303–308.

40. Handoll HH and Watts AC. Bone grafts and bone substitutes for treating distal radial fractures in adults. Cochrane Database Syst Rev 2008: CD006836.

Fussnoten

Klinik für Unfall- und Handchirurgie, Universitätsklinikum Düsseldorf

DOI 10.3228/oup.2013.0243–0247

SEITE: 1 | 2 | 3 | 4 | 5